Free testking IBM 000-180 exam certification practice questions
Saturday, November 28th, 2009Exam Number/Code: 000-180
Exam Name: p5 and pSeries Enterprise Technical Support AIX 5L V5.3
1. A customer is moving their application to a p5 590 and at the same time moving to a new version of the application. The customer knows only about the resource requirements of the old version. Which of the following is the best method to migrate their application to POWER5?
A.Add CPU and memory COD so they have room to grow if required
B.Make the server configuration twice as large as the current requirement
C.Configure the server for the current capacity requirements
D.Make the server configuration a little larger than the current capacity requirements
Answer: A
2. A customer has several AS/400 servers in their IT infrastructure running V5R2 that they wish to consolidate. The customer wants to simplify their environment and install i5/OS on a p5 590 with 16 65GHz processors and 20 i5/OS partitions. The customer plans to use the Advanced Power Virtualization to share their storage, processors, and memory. What considerations and limitations should be reviewed with the customer before the purchase?
A.Resources cannot be shared with an i5 partition when it is put on a pSeries. The i5 partition needs its own 9411-100 tower because of IOP. V5R3 OS or later is required. There is a maximum of two partitions in a 590.
B.Resources cannot be shared between partitions when i5/OS is put on a pSeries. The i5 partition needs its own 9411-100 tower because of IOP. i5/OS can be at V5R2 or a V5R3. Currently only one i5 partition is allowed.
C.V5R3 is required for the i5 partitions. Virtual IO Server is not supported for the i5/OS partitions to share storage. Up to 10 i5 partitions per processor are allowed (a maximum of two processors for up to 20 partitions).
D.Processor and memory resources can be shared between AIX 5L, Linux and i5/os partitions. i5/OS needs to be at V5R3, and Virtual IO Server is not supported for the i5/OS partition to share storage. On a 1.65 GHz POWER5 p5 590 there is a maximum of one partition.
Answer: C
3. A customer has purchased a p5 590 with 16 CPUs. To run Simultaneous Multi-Threading (SMT) with a 4-way virtual processor partition with 2.0 processing units of entitlement, how many logical CPUs will be allocated?
A.8-way logical CPU partition, where each logical CPU has the power of 25% of a logical processor
B.4-way logical CPU partition, where each logical CPU has the power of 50% of a physical processor
C.8-way logical CPU partition, where each logical CPU has the power of 25% of a physical processor
D.16-way logical CPU partition, where each logical CPU has the power of 25% of a physical processor
Answer: C
4. A customer wants to buy a new p5 570 running AIX 5.3. The applications require 4 processors and 8GB of memory. There is a requirement to have a Virtual IO Server. What is the smallest p5 570 that should be sold to this customer?
A.4 processors 8GB of memory
B.5 processors 8GB of memory
C.4 processors 10GB of memory
D.5 processors 10GB of memory
Answer: D
5. A customer has restored their mksysb. They notice that the external volume groups cannot be seen. What should be done to access the volume groups?
A.Run importvg command
B.Run synclvodm command
C.Recreate volume groups
D.Update /etc/filesystems
Answer: A
6. A customer wants to use Virtual SCSI disks to boot multiple operating systems from the same disk. How will the volumes appear in the Virtual IO Server and how will the logical volumes appear in the partition?
A.The Virtual SCSI disks are defined as logical volumes in the Virtual IO Server. The logical volumes appear as real devices (hdisks) in the client partitions.
B.The Virtual IO adapters are connected to a virtual host bridge. On the Virtual IO Server they are vdisks, on the client partition, the exported disks are visible as virtual disks.
C.The Virtual SCSI disks are represented in the ODM as a bus device whose parent is sysplanar0. Logical volumes will be assigned to the Virtual IO Server and virtual disks, vdisks, in the client partition.
D.The Virtual IO adapters are represented as adapter devices with the virtual host bridge as their parent. On the Virtual IO Server they are vdisks attached to vscsi, on the client partition the exported disks are visible as virtual disks.
Answer: A
7. A customer is purchasing a p5 595 as part of a large server consolidation. They are planning on using micropartitioning and Virtual IO to consolidate small machines. They used the rPerf numbers for AIX 5.3 to size their solutions. They discovered that their application is not yet certified on AIX 5.3, so they will have to use AIX 5.2. What changes should be made to their configuration?
A.Increase memory
B.Add more adapters
C.Increase both processors and adapters
D.Increase the number of processors by 20 – 30%
Answer: C
8. A customer has just installed a p5 595 with four uncapped LPARs in a shared processor pool. The system and profile settings are still in their default states. One of the LPARs has an application that is consuming all of the available shared processor resources. Users of this application are complaining about response time. Which of the following changes to the slow LPAR would improve response time?
A.Enable SMT
B.Reduce the weight
C.Renice the process
D.Increase the weight
Answer: D
TestKing.cc IBM 000-180 practice exam features:
Comprehensive questions with complete details, answers and references
Exhibits and graphical representations (if available)
Verified Answers Researched by Industry Experts
Questions updated on regular basis
Like actual certification exams our product is in multiple-choice questions (MCQs).
Our questions and answers are backed by our GUARANTEE.
TestKing.cc 000-180 practice exams and study questions are composed by current and active Information Technology experts, who use their experience in preparing you for your future in IT.
Popular TestKing.cc IBM Certification Exams
000-M35 : IBM Info Management Informix Dynamic Server Technical Mastery
000-P02 : IBM System p5 Low-End AIX 5L Sales
000-974 : Power Systems Technical Support for i
000-415 : IBM WebSphere IIS DataStage Enterprise Edition v7.5
000-237 : pSeries HACMP for AIX 5L
000-215 : test 215,ibm websphere commerce v5.6,implementation
000-M32 : IBM Information Management pureXML Technical Sales Mastery
000-994 : Test994, IBM WebSphere MQ V6.0,System Administration
000-789 : IBM Tivoli Storage Resource Manager V1.2 Implementation
000-331 : Power Systems Sales for AIX and Linux
000-222 : P5 and pSeries Administration and Support for AIX 5L V5.3
000-180 : p5 and pSeries Enterprise Technical Support AIX 5L V5.3